AIRPATH INSTRUMENT CO -- COMPASS FLUID -- 6810-00-290-0051
===================== Product Identification ===================== Product ID:COMPASS FLUID MSDS Date:01/01/1998 FSC:6810 NIIN:00-290-0051 === Responsible Party === Company Name:AIRPATH INSTRUMENT CO Address:13150 GIST ROAD City:BRIDGETON State:MO ZIP:63044 Country:US Info Phone Num:314-739-8117/8118 Emergency Phone Num:314-739-8117 Preparer's Name:NOT PROVIDED. CAGE:70214 === Contractor Identification === Company Name:AIRPATH INSTRUMENT CO Address:13150 TAUSSING AVE Box:City:BRIDGETON State:MO ZIP:63044 Country:US Phone:314-739-8117/8118 CAGE:70214 Company Name:EMULTEC INDUSTRIAL PRODUCTS INC Address:1150 HAYDEN DR SUITE 100 Box:City:CHARROLLTON State:TX ZIP:75006 Country:US Phone:972-417-1288 Contract Num:SP0450-00-M-D348 CAGE:0WA27 Company Name:HOOSIER INDUSTRIAL SUPPLY Address:1223 CHICAGO AVE Box:City:GOSHEN State:IN ZIP:46527-0929 Country:US Phone:219-533-8565 Contract Num:SP0450-00-M-SD08 CAGE:0RCD8 Company Name:LOS ANGELES CHEMICAL CO Address:4545 ARDINE ST Box:1987 City:SOUTH GATE State:CA ZIP:90280 Country:US Phone:213-562-9500 CAGE:75656 ============= Composition/Information on Ingredients ============= Ingred Name:ISOALKANES/MIXTURE OF C10-C13 ISOPARAFFINS CAS:68551-17-7 Other REC Limits:400 PPM ===================== Hazards Identification ===================== Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE: RECOMMENDED EXPOSURE LIMIT 400 PPM. CHRONIC: NO KNOWN APPLICATION LIMIT. Explanation of Carcinogenicity:NONE Effects of Overexposure:MAY BE IRRITATING TO EYES. STRONG SKIN IRRITANT. MAY CAUSE HEADACHES, DIZZINESS, NAUSEA, UNCONSCIOUSNESS. MAY BE ASPIRATION HAZARD IF SWALLOWED. MAY IRRITATE STOMACH AND INTESTINES. Medical Cond Aggravated by Exposure:NO KNOWN APPLICABLE INFORMATION. SEE SIGNS AND SYMPTOMS OF EXPOSURE NOTED ABOVE. ======================= First Aid Measures ======================= First Aid:INHALATION: REMOVE FROM COMTAMINATED AIR. IF ILLNESS DEVELOPS, CONSULT A PHYSICIAN. EYES: IMMEDIATELY FLUSH EYES WITH WATER FOR 15 MINUTES. IF IRRITATION PERSISTS, CONSULT A PHYSICIAN. SKIN: IMMEDIATE LY WASH WITH SOAP AND WATER AND SEEK PROMPT MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. IF SWALLOWED, CONSULT A PHYSICIAN IMMEDIATELY. ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:=56.1C, 133.F Autoignition Temp:Autoignition Temp Text:N/E Lower Limits:N/E Upper Limits:N/E Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE OR FOAM. Fire Fighting Procedures:SHUT OFF SOURCE. USE WATER FOG OR SPRAY TO COOL EXPOSED EQUIPMENT AND CONTAINERS. WEAR SELF-CONTAINED BREATHING APPARATUS. Unusual Fire/Explosion Hazard:COMBUSTIBLE LIQUID. PROTECT FROM SOURCES OF IGNITION. ================== Accidental Release Measures ================== Spill Release Procedures:PROTECT FROM IGNITION. CONTAIN SPILL. KEEP OUT OF WATER SOURCES AND SEWERS. ABSORB IN DRY INERT MATERIAL (SAND, CLAY, SAW DUST, ETC..). REFER TO PERSONAL PROTECTION INFORAMTION. CONTACT APPROPRIATE SA FETY PERSONNEL FOR RESPIRATOR REQUIREMENTS. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED AREA. PROTECT FROM SOURCES OF IGNITION. PROVIDE MEANS OF CONTROLLING LEAKS OR SPILLS. BOND AND GROUND DURING LIQUID TRANSFER. Other Precautions:AVOID INHALATION AND SKIN AND EYE CONTACT. WEAR PROTECTIVE EQUIPMENT. WASH HANDS BEFORE EATING, DRINKING OR SMOKING. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NOT GENERALLY REQUIRED UNLESS NEEDED TO PREVENT RESPIRATORY IRRITATION. Ventilation:USE ADEQUATE VENTILATION. LOCAL EXHAUST IF REQUIRED . Protective Gloves:RUBBER, NEOPRENE OR VINYL ALCOHOL. Eye Protection:CHEMICAL GOGGLES AND FACE SHIELD FOR SPLASH PROTECTION. Other Protective Equipment:USE PROTECTIVE GARMENTS TO PREVENT SKIN CONTACT. Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHING BEFORE USE. Supplemental Safety and Health NONE ================== Physical/Chemical Properties ================== HCC:F4 NRC/State Lic Num:NOT RELEVANT Boiling Pt:B.P. Text:349F - 406F Melt/Freeze Pt:M.P/F.P Text:NOT ESTABLISHED. Vapor Pres:118.1 @70F Vapor Density:>1 Spec Gravity:0.75@60F pH:NOT RELEVANT. Solubility in Water:NEGLIGIBLE Appearance and Odor:COLORLESS LIQUID, MILD ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZING AGENTS OR OXYGEN. Stability Condition to Avoid:NOT PROVIDED. Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE. =================== Toxicological Information =================== Toxicological Information:NOT PROVIDED. ===================== Ecological Information ===================== Ecological:NOT PROVIDED. ==================== Disposal Considerations ==================== Waste Disposal Methods:INCINERATE UNDER CONTROLLED CONDITION OR PLACE IN RCRA PERMITTED WASTE MANAGEMENT FACILITY. =================== MSDS Transport Information =================== Transport Information:PETROLEUM DISTILLATES, N.O.S. (ISOPARAFFINIC HYDROCARBONS), 3 (FLAMMABLE LIQUID), UN1268, PG-III, LABEL FLAMMABLE LIQUID, PACKAGING REFERENCE: 49 CFR 173.150, 173.203, 173.242. NOTE: THIS PRODUCT MAY BE RECLASSED AS A COMBUSTIBLE LIQUID WHEN SHIPPED DOMESTICALLY, BY LAND ONLY. IF RECLASSED AS A COMBUSTIBLE LIQUID, THIS PRODUCT IS UNREGULATED BY DOT WHEN SHIPPED IN NON-BULK QUANTITIES (<119 GAL.) ===================== Regulatory Information ===================== SARA Title III Information:NOT PROVIDED. Federal Regulatory Information:THIS PRODUCT MEETS THE DEFINITION(S) OF THE OSHA COMMUNICATION STANDARD (29 CFR 1910.1200). State Regulatory Information:NOT PROVIDED. ======================= Other Information ======================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.